PySide6.QtSerialBus.QModbusRtuSerialServer

class QModbusRtuSerialServer

The QModbusRtuSerialServer class represents a Modbus server that uses a serial port for its communication with the Modbus client. More

Inheritance diagram of PySide6.QtSerialBus.QModbusRtuSerialServer

Synopsis

Methods

Note

This documentation may contain snippets that were automatically translated from C++ to Python. We always welcome contributions to the snippet translation. If you see an issue with the translation, you can also let us know by creating a ticket on https:/bugreports.qt.io/projects/PYSIDE

Detailed Description

Communication via Modbus requires the interaction between a single Modbus client instance and multiple Modbus server. This class provides the Modbus server implementation via a serial port.

Since multiple Modbus server instances can interact with a Modbus client at the same time (using a serial bus), servers are identified by their serverAddress() .

__init__([parent=None])
Parameters:

parentQObject

Constructs a QModbusRtuSerialServer with the specified parent. The serverAddress preset is 1.

interFrameDelay()
Return type:

int

Returns the amount of microseconds for the silent interval between two consecutive Modbus messages.

setInterFrameDelay(microseconds)
Parameters:

microseconds – int

Sets the amount of microseconds for the silent interval between two consecutive Modbus messages. By default, the class implementation will use a pre-calculated value according to the Modbus specification. A active or running connection is not affected by such delay changes.

Note

If microseconds is set to -1 or microseconds is less than the pre-calculated delay then this pre-calculated value is used as frame delay.