- class QModbusReply¶
The
QModbusReply
class contains the data for a request sent with aQModbusClient
derived class. More…Synopsis¶
Methods¶
def
__init__()
def
error()
def
errorString()
def
isFinished()
def
rawResult()
def
result()
def
serverAddress()
def
setError()
def
setFinished()
def
setRawResult()
def
setResult()
def
type()
Signals¶
def
errorOccurred()
def
finished()
Note
This documentation may contain snippets that were automatically translated from C++ to Python. We always welcome contributions to the snippet translation. If you see an issue with the translation, you can also let us know by creating a ticket on https:/bugreports.qt.io/projects/PYSIDE
Detailed Description¶
- class ReplyType¶
This enum describes the possible reply type.
Constant
Description
QModbusReply.Raw
The reply originates from a raw Modbus request. See
sendRawRequest
QModbusReply.Common
The reply originates from a common read, write or read/write request. See
sendReadRequest
,sendWriteRequest
andsendReadWriteRequest
QModbusReply.Broadcast
The reply originates from a Modbus broadcast request. The
serverAddress()
will return0
and thefinished()
signal will be emitted immediately.
- __init__(type, serverAddress[, parent=None])¶
Constructs a
QModbusReply
object with a giventype
and the specifiedparent
.The reply will be sent to the Modbus client represented by
serverAddress
.- addIntermediateError(error)¶
- Parameters:
error –
IntermediateError
Returns the error state of this reply.
See also
This signal is emitted when an error has been detected in the processing of this reply. The
finished()
signal will probably follow.The error will be described by the error code
error
. IferrorString
is not empty it will contain a textual description of the error. In case of aProtocolError
therawResult()
function can be used to obtain the original Modbus exception response to get the exception code.Note: Do not delete this reply object in the slot connected to this signal. Use deleteLater() instead.
See also
- errorString()¶
- Return type:
str
Returns the textual representation of the error state of this reply.
If no error has occurred this will return an empty string. It is possible that an error occurred which has no associated textual representation, in which case this will also return an empty string.
See also
- finished()¶
This signal is emitted when the reply has finished processing. The reply may still have returned with an error.
After this signal is emitted, there will be no more updates to the reply’s data.
Note
Do not delete the object in the slot connected to this signal. Use deleteLater().
You can also use
isFinished()
to check if a QNetworkReply has finished even before you receive the finished() signal.See also
- intermediateErrorOccurred(error)¶
- Parameters:
error –
IntermediateError
- intermediateErrors()¶
- Return type:
.list of QModbusDevice.IntermediateError
Returns the list of intermediate errors that might have happened during the send-receive cycle of a Modbus request until the
QModbusReply
reports to be finished.- isFinished()¶
- Return type:
bool
Returns
true
when the reply has finished or was aborted.See also
- rawResult()¶
- Return type:
Returns the raw response of a Modbus request.
If the request has not finished then the returned
QModbusResponse
instance is invalid.- result()¶
- Return type:
Returns the preprocessed result of a Modbus request.
For read requests as well as combined read/write requests send via
sendReadWriteRequest()
it contains the values read from the server instance.If the request has not finished, has failed with an error or was a write request then the returned
QModbusDataUnit
instance is invalid.Note
If the
type()
of the reply isBroadcast
, the return value will always be invalid. If thetype()
of the reply isRaw
, the return value might be invalid depending on the implementation ofprocessPrivateResponse()
.See also
- serverAddress()¶
- Return type:
int
Returns the server address that this reply object targets.
- setFinished(isFinished)¶
- Parameters:
isFinished – bool
- setRawResult(unit)¶
- Parameters:
unit –
QModbusResponse
- setResult(unit)¶
- Parameters:
unit –
QModbusDataUnit
Returns the type of the reply.